| Id | Activity | Value | Uom | Description | Remarks | Source |
| 1 | Process Isolation | 0.25 | h/conn. | Time needed to close a SBB and to check proper isolation | expert judgment | |
| 2 | Process Isolation | 0.50 | h/conn. | Time needed to close a DBB and to check proper isolation | expert judgment | |
| 3 | Depressurization | 0.50 | h | Time needed to reach atmospheric pressure by opening BDV and discharging to flare | expert judgment | |
| 4 | Cool down | ○ | ○ | See dedicated table | expert judgment | |
| 5 | Electrical Isolation | 0.25 | h | Time needed to locate and disconnect the circuit breaker and to verify isolation in field according to HSE procedures | expert judgment | |
| 6 | Draining | 0.50 | h | Time needed to open connections to drain system (or to connect temporary lines) | expert judgment | |
| 7 | Draining | 2.50 | m/s | Liquid velocity in the draining line | expert judgment | |
| 8 | Purging | 0.50 | h | Time needed to connect the nitrogen generator | expert judgment | |
| 9 | Purging | 2.00 | bar | Pressurization pressure (applicable to purging by pressurization/depr. cycles) | expert judgment | |
| 10 | Purging | 1.00 | bar | Discharge pressure (applicable to purging by pressurization/depr. cycles) | expert judgment | |
| 11 | Purging | 1,400.00 | Sm3/h | Nitrogen generator flow rate | TO BE DEFINED BASED ON PROJECT | PROJECT SOURCE |
| 12 | Purging | 3.00 | n/a | Sweeping factor | expert judgment | |
| 13 | Blinding | 0.50 | h/conn. | Time needed to apply/remove positive isolation devices (i.e. spectacles, blind flanges, spools) | expert judgment | |
| 14 | Ventilation | 0.50 | h | Time needed to open a manway | expert judgment | |
| 15 | Ventilation | 1.00 | min/m3 | Time needed for ventilation | expert judgment | |
| 16 | Ventilation | 24.00 | h | Maximum ventilation time | expert judgment | |
| 17 | Washing | ○ | ○ | See dedicated table | ENI Std. 20560_430_rev02 | |
| 18 | Item Removal | ○ | ○ | See dedicated table | expert judgment | |
| 19 | Reinstalling | 0.50 | h/conn. | Time needed to remove positive isolation devices or to reinstall spools | expert judgment | |
| 20 | Reinstalling | 0.25 | h/conn. | Time needed to open isolation valves | expert judgment |